Fire Performance of Electric Cables

Often Savings of the best flame retardant cables are halogenated as a result of each the insulation and outer Jacket are flame retardant however when we want Halogen Free cables we find it’s often solely the outer jacket which is flame retardant and the inside insulation is not.
This has significance as a outcome of while cables with a flame retardant outer jacket will often move flame retardance checks with exterior flame, the identical cables when subjected to excessive overload or extended brief circuits have proved in college exams to be extremely flammable and might even start a fire. This effect is understood and published (8th International Conference on Insulated Power Cables (Jicable’11 – June 2011) held in Versailles, France) so it’s perhaps surprising that there are not any common take a look at protocols for this seemingly frequent event and one cited by each authorities and media as explanation for building fires.
Further, in Flame Retardant take a look at strategies similar to IEC60332 components 1 & 3 which make use of an external flame supply, the cable samples aren’t pre-conditioned to regular operating temperature but tested at room temperature. This oversight is necessary particularly for power circuits as a end result of the temperature index of the cable (the temperature at which the cable materials will self-support combustion in normal air) might be considerably affected by its beginning temperature i.e.: The hotter the cable is, the more simply it’ll propagate fire.
It would seem that a need exists to re-evaluate current cable flame retardance take a look at strategies as these are commonly understood by consultants and consumers alike to supply a reliable indication of a cables capacity to retard the propagation of fire.
If we can’t belief the Standards what will we do?
In the USA many constructing requirements do not require halogen free cables. Certainly this is not because Americans aren’t wisely knowledgeable of the risks; rather the method taken is that: “It is healthier to have extremely flame retardant cables which do not propagate fireplace than minimally flame retardant cables which can spread a fire” – (a small fire with some halogen may be higher than a big fireplace with out halogens). One of the best methods to make a cable insulation and cable jacket extremely flame retardant is through the use of halogens.
Europe and many international locations around the globe adopt a unique mentality: Halogen Free and Flame Retardant. Whilst that is an admirable mandate the reality is somewhat different: Flame propagation checks for cables as adopted in UK and Europe can arguably be stated to be much less stringent than a few of the flame propagation exams for cables in USA resulting in the conclusion that frequent checks in UK and Europe could merely be checks the cables can pass quite than checks the cables should cross.
Conclusion
For most versatile polymeric cables the selection stays today between high flame propagation performance with halogens or reduced flame propagation performance without halogens.
Enclosing cables in steel conduit will cut back propagation on the point of fire however hydrocarbon based mostly combustion gasses from decomposing polymers are doubtless propagate via the conduits to switchboards, distribution boards and junction packing containers in other elements of the constructing. Any spark such as the opening or closing of circuit breakers, or contactors is prone to ignite the combustible gasses resulting in explosion and spreading the hearth to a different location.
While MICC (Mineral Insulated Metal Sheathed) cables would supply a solution, there might be often no singe perfect answer for every set up so designers need to judge the required performance on a “project-by-project” foundation to decide which expertise is perfect.
The major importance of fireside load
Inside all buildings and projects electrical cables present the connectivity which retains lights on, air-conditioning working and the lifts working. It powers computers, workplace equipment and provides the connection for our phone and computers. Even Ultimate need to connect with wireless or GSM antennas which are related to the telecom network by fiber optic or copper cables. Cables guarantee our security by connecting
hearth alarms, emergency voice communication, CCTV, smoke shutters, air pressurization fans, emergency lighting, fireplace sprinkler pumps, smoke and warmth detectors, and so many other features of a contemporary Building Management System.
Where public security is essential we regularly request cables to have added safety features such as flame retardance to make sure the cables do not simply spread fireplace, circuit integrity during hearth in order that essential fire-fighting and life safety gear hold working. Sometimes we may recognize that the combustion of electric cables produces smoke and this could be poisonous so we call for cables to be Low Smoke and Halogen Free. Logically and intuitively we predict that by requesting these special properties the cables we buy and set up will be safer
Because cables are put in by many different trades for various functions and are mostly hidden or embedded in our constructions, what is commonly not realized is that the various miles of cables and tons of plastic polymers which make up the cables can characterize one of the largest fire hundreds in the building. This level is definitely worth considering more about.
PVC, XLPE, EPR, CSP, LSOH (Low Smoke Zero Halogen) and even HFFR (Halogen Free Flame Retardant) cable supplies are largely based mostly on hydrocarbon polymers. These base supplies usually are not typically flame retardant and naturally have a excessive fireplace load. Cable manufacturers make them flame retardant by adding compounds and chemical substances. Certainly this improves the volatility of burning however the gas content material of the bottom polymers stays.
Tables 1 and 2 above compare the fireplace load in MJ/Kg for frequent cable insulating materials towards some widespread fuels. The Heat Release Rate and volatility in air for these supplies will differ but the fuel added to a fire per kilogram and the consequential quantity of heat generated and oxygen consumed is relative.
The volume in kilometers and tons of cables installed in our buildings and the related fireplace load of the insulations is appreciable. This is especially important in tasks with lengthy egress occasions like high rise, public buildings, tunnels and underground environments, airports, hospitals and so forth.
When contemplating fireplace safety we must first understand the most important components. Fire experts inform us most hearth related deaths in buildings are attributable to smoke inhalation, temperature rise and oxygen depletion or by trauma caused by leaping in trying to flee these effects.
Smoke
The first and most necessary aspect of smoke is how much smoke? Typically the larger the hearth the more smoke is generated so something we are ready to do to cut back the unfold of fireside will also correspondingly reduce the amount of smoke.
Smoke will include particulates of carbon, ash and different solids, liquids and gasses, many are toxic and combustible. In particular, fires in confined areas like buildings, tunnels and underground environments trigger oxygen ranges to drop, this contributes to incomplete burning and smoldering which produces elevated amounts of smoke and poisonous byproducts together with CO and CO2. Presence of halogenated materials will launch poisonous Halides like Hydrogen Chloride along with many other poisonous and flammable gasses in the smoke.
For this cause widespread smoke exams carried out on cable insulation materials in massive three meter3 chambers with loads of air can present deceptive smoke figures as a result of complete burning will typically launch significantly much less smoke than partial incomplete burning which is in all probability going in apply. Simply specifying IEC 61034 with an outlined obscuration worth then thinking this will present a low smoke surroundings throughout hearth might sadly be little of assist for the individuals really concerned.
Halogens, Toxicity, Fuel Element, Oxygen Depletion and Temperature Rise
It is regarding that Europe and different countries undertake the concept of halogen free materials with out correctly addressing the topic of toxicity. Halogens launched during combustion are extremely toxic but so too is carbon monoxide and this is not a halogen gasoline. It is common to call for halogen free cables and then enable using Polyethylene because it’s halogen free. Burning Polyethylene (which may be seen from the table above has the very best MJ fuel load per Kg of all insulations) will generate virtually three occasions extra heat than an equal PVC cable. This means is that burning polyethylene is not going to solely generate almost 3 times extra heat but also consume nearly three times extra oxygen and produce considerably extra carbon monoxide. Given carbon monoxide is liable for most toxicity deaths in fires this situation is at greatest alarming!
The gas components proven in the table above point out the amount of heat which might be generated by burning 1kg of the widespread cable insulations tabled. Certainly this heat will speed up the burning of different adjoining supplies and should assist spread the fireplace in a building however importantly, to find a way to generate the warmth energy, oxygen must be consumed. The greater the heat of combustion the extra oxygen is required, so by choosing insulations with excessive gasoline parts is including significantly to at least 4 of the primary dangers of fires: Temperature Rise, Oxygen Depletion, Flame Spread and Carbon Monoxide Release.
Perhaps it is best to put in polymeric cables inside steel conduits. This will definitely help flame unfold and decrease smoke as a result of contained in the conduit oxygen is restricted; nonetheless this isn’t an answer. As mentioned previously, most of the gasses from the decomposing polymeric insulations contained in the conduits are highly flammable and toxic. These gases will migrate alongside the conduits to junction boxes, switch panels, distribution boards, motor control centers, lamps, switches, and so forth. On coming into the gases can ignite or explode with any arcing such because the make/break of a circuit breaker, contactor, swap or relay causing the fireplace to spread to another location.
Conclusion
The popularity of “Halogen Free” whereas ignoring the opposite poisonous parts of fire is a transparent admission we don’t understand the subject properly nor can we simply outline the risks of combined toxic parts or human physiological response to them. It is necessary nonetheless, that we do not continue to design with only half an understanding of the issue. While no good resolution exists for natural based cables, we will actually reduce these critically important effects of fire danger:
One choice perhaps to choose cable insulations and jacket materials that are halogen free and have a low fuel component, then set up them in metal conduit or maybe the American method is best: to make use of highly halogenated insulations in order that in case of fire any flame unfold is minimized.
For most power, management, communication and knowledge circuits there might be one full resolution obtainable for all the issues raised in this paper. It is an answer which has been used reliably for over eighty years. MICC cables can provide a complete and full answer to all the issues related to the fireplace safety of organic polymer cables.
The copper jacket, magnesium oxide insulation and copper conductors of MICC ensure the cable is successfully fire proof. MICC cables don’t have any natural content material so merely cannot propagate flame or generate any smoke. The zero gas load ensures no heat is added and no oxygen is consumed.
Being inorganic MICC cables can’t generate any halogen or poisonous gasses at all together with CO.
Unfortunately many common cable fire take a look at strategies used right now might inadvertently mislead folks into believing the polymeric versatile cable products they purchase and use will perform as expected in all fire situations. As outlined on this paper, sadly this will not be appropriate.
For extra info, go to www.temperature-house.com